MM Aqua & Munters Fills Dealer
The MM Aqua range of Munters-designed cooling tower media. It includes C-series and vertical-flute film fill, trickle grid and V-bar splash fill, drift and mist eliminators and distribution nozzles. We supply against your model number or your tower data.
- Munters-designed film fill media
- C10.12 through C10.27 and VFO-20
- Drift and mist eliminators, nozzles
- Media to CTI STD 136 (2010)
About Us
Since 2016, CJP has supplied, manufactured and serviced plate heat exchangers for industry and OEMs across India. From our Chennai works we make gasketed units, cooling tower fills and replacement plates and gaskets, and our crews install and service them.
We are a dealer for MM Aqua and Munters fills, and match the specification to your model designation or tower data.
Our Clients























MM Aqua & Munters Fills Dealer
A tower built around branded media is usually refilled by model, not by description. A C10.19 pack is not a C10.12 pack. A drift eliminator of a different pitch will not sit on the existing supports. The range below is listed by MM Aqua designation, with the figures the manufacturer publishes. You can match a specification before you order.
Send the model designation from the existing media if you have it. If not, send your tower data and water quality.
Film Fill — C Series
Cross-corrugated virgin PVC, UV protected, to CTI STD 136 (2010). Choose the flute size by the water, not the duty: a finer flute gives more surface area but needs cleaner water. Standard pack L 1200 × W 300 × H 300 mm. Supports max. 1000 mm apart, at least 50 mm wide.Film Fill — Vertical & Offset Flute
For duties where fouling is the main problem, not thermal performance. Vertical channels pass solids that would bridge a cross-corrugated pack. Virgin PVC, with supports max. 1000 mm apart, at least 50 mm wide.Splash Fill
For water that would foul a film pack: high solids, oil and grease, or temperatures above what PVC film media can take.Drift Eliminators
Pitch and support span decide what fits. All three are rated to 55 °C.Mist Eliminators
Droplet separation profiles. Send the designation, or measure the profile depth of what is fitted now.Distribution Nozzles
Water distribution for counterflow towers, and for bio-tower and trickling filter duties.Send Us the Details
Send the model designation from the existing media if you have it. If not, send your tower data and water quality.
Frequently Asked Questions
01How do we choose the right fill for our tower?
The water quality and the tower supports decide it. Send us the tower type (RCC or FRP), the dimensions, the circulating water flow, the hot and cold water temperatures and the design wet bulb. Tell us the suspended solids and the water treatment in use. We recommend film fill for clean water and splash fill where solids would block a film pack.
02Can you supply a fill to match what is in our tower now?
Yes. Send a photo of the current fill on its supports, and its model designation if you have it. Add the support spacing or bench tie layout. We match the type, pack size and fit to the existing supports.
03How do we work out the quantity?
From the fill volume in the tower: internal length, width and fill height. You can quote the quantity in cubic metres or in pieces. If you are not sure, send the tower dimensions and we calculate it for you.
04Do you deliver, and can you remove the old fill?
We quote freight to your plant with the fill. Tell us the tower location and whether you want the old fill removed. We confirm delivery timing with the quotation.